DVR 2proVacuum gauge

Overview

  • improved functionality within the navigation menu helps to save energy and to increase the life cycle of the battery
  • large, graphical analog display with digital measuring values alows to detect tendencies and makes it easier to readout precisely
  • pressure unit user-selectable in mbar, hPa or Torr prevents unnecessary conversions
  • different vacuum connections and the additional support rod allow the use in almost every laboratory application
  • chemical resistant materials for wetted parts together with the capacitive ceramic diaphragm pressure sensor provide excellent long-term stability and accuracy
Cat. No.
20682906
$1,260.00
- +

Inquire

Vacuum gauge in action

The DVR 2pro is a fully electronic, versatile vacuum gauge for the measuring range from atmospheric pressure to 1 mbar. All wetted parts are made from enhanced chemical resistant material which allows the use under very rough laboratory conditions. The high accuracy and the large graphical display from the DVR 2 have also been carried forward for the “pro” version. One of the main enhancements is the power supply with a normal 9 V Alkaline battery. The new battery slot at the back of the gauge allows for easy replacement of the battery. A wider range of connection parts provide a great range of connection flexibility for laboratory use.

für Zoom klicken

Technical data and graphs

Upper measuring limit in mbar/hPa 1060 mbar
Upper measuring limit in torr 795 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Automatic switch-off User-selectable: 1-600 min (default 5 min) or continuous operation min
Measurement cycle User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Power supply 9 V battery
Weight 0.4 kg
Dimension L in mm 115 mm
Dimension B in mm 115 mm
Dimension H in mm 90 mm
Vacuum sensor Integr.
Typical battery lifetime 4.000 h, stand-by: 30.000 h h
NRTL certification No
Items supplied Vacuum gauge complete with integrated vacuum sensor, including battery 9 V alkali-manganese, support rod, connecting parts and manual.

Downloads

Vacuum gauge DVR 2pro, 1080 - 1 mbar*** Alkaline-Manganese Dioxide-Zinc-Batteries! Not restricted - No dangerous goods transportaccording IATA SP A123 and ADR/RID/IMDG code. ***
Manual vacuum gauge / controller
Manual PDF 6.6 MB 6.6 MB 7.8 MB 6.6 MB 4.9 MB
Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download

Related Products

Vacuum gauge in action

The DVR 2pro is a fully electronic, versatile vacuum gauge for the measuring range from atmospheric pressure to 1 mbar. All wetted parts are made from enhanced chemical resistant material which allows the use under very rough laboratory conditions. The high accuracy and the large graphical display from the DVR 2 have also been carried forward for the “pro” version. One of the main enhancements is the power supply with a normal 9 V Alkaline battery. The new battery slot at the back of the gauge allows for easy replacement of the battery. A wider range of connection parts provide a great range of connection flexibility for laboratory use.

für Zoom klicken

Technical data and graphs

Upper measuring limit in mbar/hPa 1060 mbar
Upper measuring limit in torr 795 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Automatic switch-off User-selectable: 1-600 min (default 5 min) or continuous operation min
Measurement cycle User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Power supply 9 V battery
Weight 0.4 kg
Dimension L in mm 115 mm
Dimension B in mm 115 mm
Dimension H in mm 90 mm
Vacuum sensor Integr.
Typical battery lifetime 4.000 h, stand-by: 30.000 h h
NRTL certification No
Items supplied Vacuum gauge complete with integrated vacuum sensor, including battery 9 V alkali-manganese, support rod, connecting parts and manual.

Downloads

Vacuum gauge DVR 2pro, 1080 - 1 mbar*** Alkaline-Manganese Dioxide-Zinc-Batteries! Not restricted - No dangerous goods transportaccording IATA SP A123 and ADR/RID/IMDG code. ***
Manual vacuum gauge / controller
Manual PDF 6.6 MB 6.6 MB 7.8 MB 6.6 MB 4.9 MB
Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download

Related Products