Single-channel micropipette Transferpette® S, adjustable, DE-M

Overview

  • Efficient: one-hand operation
  • Flexible: ergonomic design for all hand sizes
  • Reliable: volume-change protection prevents accidental adjustments

Choose your product:

Volume range:
0.1 - 1 µl
0.1 - 2.5 µl
0.5 - 10 µl
2 - 20 µl
5 - 50 µl
10 - 100 µl
20 - 200 µl
100 - 1,000 µl
500 - 5,000 µl
1,000 - 10,000 µl
No products found that match your set filters
Product:
Choose an option
Clear selection

Upon Request

Inquire

Grouped product items
Cat.-No. Volume range Model Accuracy in % (±) Accuracy in µl (±) Coefficient of variation (%) Coefficient of variation (µl) Recommended tip size Number of channels
705868 0.1 - 1 µl D-1 2 % 0.02 µl 1.2 % 0.012 µl 0,1 - 20 single-channel
705869 0.1 - 2.5 µl D-2,5 1.4 % 0.035 µl 0.7 % 0.018 µl 0,5 - 20 single-channel
705870 0.5 - 10 µl D-10 1 % 0.1 µl 0.5 % 0.05 µl 0,5 - 20 single-channel
705872 2 - 20 µl D-20 0.8 % 0.16 µl 0.4 % 0.08 µl 2 - 200 single-channel
705873 5 - 50 µl D-50 0.8 % 0.4 µl 0.3 % 0.15 µl 2 - 200 single-channel
705874 10 - 100 µl D-100 0.6 % 0.6 µl 0.2 % 0.2 µl 2 - 200 single-channel
705878 20 - 200 µl D-200 0.6 % 1.2 µl 0.2 % 0.4 µl 2 - 200 single-channel
705880 100 - 1,000 µl D-1000 0.6 % 6 µl 0.2 % 2 µl 50 - 1000 single-channel
705882 500 - 5,000 µl D-5000 0.6 % 30 µl 0.2 % 10 µl 500 - 5000 single-channel
705884 1,000 - 10,000 µl D-10000 0.6 % 60 µl 0.2 % 20 µl 1000 - 10000 single-channel
Grouped product items
Price per Price
Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Product Detail

The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:

Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)

Vapor pressure up to 500 mbar

Viscosity: 260 mPa s

For viscous media, the speed must be adjusted if necessary.

Items supplied

Transferpette® S, adjustable-volume model, supplied with performance certificate, shelf mount and silicone grease

für Zoom klicken

Videos

Youtube preview image
Youtube preview image
Grouped product items
Cat.-No. Volume range Model Accuracy in % (±) Accuracy in µl (±) Coefficient of variation (%) Coefficient of variation (µl) Recommended tip size Number of channels
705868 0.1 - 1 µl D-1 2 % 0.02 µl 1.2 % 0.012 µl 0,1 - 20 single-channel
705869 0.1 - 2.5 µl D-2,5 1.4 % 0.035 µl 0.7 % 0.018 µl 0,5 - 20 single-channel
705870 0.5 - 10 µl D-10 1 % 0.1 µl 0.5 % 0.05 µl 0,5 - 20 single-channel
705872 2 - 20 µl D-20 0.8 % 0.16 µl 0.4 % 0.08 µl 2 - 200 single-channel
705873 5 - 50 µl D-50 0.8 % 0.4 µl 0.3 % 0.15 µl 2 - 200 single-channel
705874 10 - 100 µl D-100 0.6 % 0.6 µl 0.2 % 0.2 µl 2 - 200 single-channel
705878 20 - 200 µl D-200 0.6 % 1.2 µl 0.2 % 0.4 µl 2 - 200 single-channel
705880 100 - 1,000 µl D-1000 0.6 % 6 µl 0.2 % 2 µl 50 - 1000 single-channel
705882 500 - 5,000 µl D-5000 0.6 % 30 µl 0.2 % 10 µl 500 - 5000 single-channel
705884 1,000 - 10,000 µl D-10000 0.6 % 60 µl 0.2 % 20 µl 1000 - 10000 single-channel
Grouped product items
Price per Price
Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Upon request

Inquire

Product Detail

The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:

Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)

Vapor pressure up to 500 mbar

Viscosity: 260 mPa s

For viscous media, the speed must be adjusted if necessary.

Items supplied

Transferpette® S, adjustable-volume model, supplied with performance certificate, shelf mount and silicone grease

für Zoom klicken

Videos

Youtube preview image
Youtube preview image